Features
Features
MODELS | PR70e with LCM | PR70e with DM | PR70 with ADM | PR70v with ADM | PR70f with ADM | PR70 with Servo | |
---|---|---|---|---|---|---|---|
System | Configured System | No | Yes | Yes | Yes | No | No |
Ratios | Fixed Ratio | 1:1 to 12:1 | 1:1 to 12:1 | 1:1 to 12:1 | NA | 1:1 to 12:1 | 1:1 to 12:1 |
Variable Ratio | NA | NA | NA | 1:1 to 24:1 | 1:1 to 24:1 | 1:1 to 24:1 | |
Shots | Number of Shots | 1 | 5 | 50 | 50 | 50 | 10 |
Based on Percentage of Stroke | Yes | No | No | No | No | No | |
Weight Based Shots | No | Yes | Yes | Yes | Yes | No | |
Multi-stroke shots (over 100%) | No | Yes | Yes | Yes | Yes | Yes | |
Shot Sequencing | No | Optional | Yes | Yes | Yes | No | |
Monitoring | Pressure Monitoring | No | Optional | Optional | Optional | Optional | Optional |
Ratio Monitoring | No | Optional | Optional | Optional | Optional | No | |
Data Controls | Local Control Module | Yes | No | No | No | No | No |
Display Module | No | Yes | No | No | No | No | |
Advanced Display Module | No | Optional | Yes | Yes | Yes | No | |
Gel Timer | No | Yes | Yes | Yes | Yes | Yes | |
Run with Automation | No | Yes | Yes | Yes | Yes | Yes | |
USB Download | No | Optional | Yes | Yes | Yes | Optional | |
Light Tower | No | No | Optional | Optional | Optional | Optional | |
Flow Control | Flood Control | No | No | No | No | Yes | Yes |
Flow Range | N/A | N/A | N/A | N/A | 0.014-226 | 0-47 | |
PLC Flow Selections | N/A | N/A | N/A | N/A | 15 | Infinite | |
Bead Control | No | No | No | No | Yes | Yes | |
Snake Head Control | No | No | No | No | Yes | Yes | |
Pump Reloading Capability | No | No | No | No | Yes | Yes | |
Bead/Dispense Pausing | No | No | No | No | Yes | Yes | |
Remote Analog Flow Control | No | No | No | No | No | Yes |
Metering Pump Effective Area | 0.124 – 1.49 in2 (80 – 960 mm2 ) per side |
---|---|
Small Air Cylinder Effective Area | 7.07 in2 (4560 mm2) |
Large Air Cylinder Effective Area | 15.9 in2 (10260 mm2 |
Maximum Stroke Length | 1.50 in (38.1 mm) |
Minimum Stroke Length | 0.23 in (5.8 mm) |
Volume per Cycle | 0.12 – 4.3 in3 (2 – 70 cc |
Pump Cycles per 1L (.26 gal) | 500 – 14.3 |
Ratios (fixed) | 1:1 to 12:1 depending on cylinders selected |
Ratios (variable) | 1:1 to 24:1 depending on cylinders selected |
Maximum Fluid Working Pressure | 3000 psi (207 bar, 20.7 MPa) |
Maximum Air Input Pressure | 100 psi (7 bar, 0.7 MPa) |
Maximum Cycle Rate. | 30 cpm |
Maximum Operating Temperatur | 70° C (160° F) nylon pistons 50° C (120° F) UHMWPE pistons or PE tanks |
Air Inlet Size | 1/4 NPT(f) |
Pump Fluid Outlet Size | -03, -04, -06, -08 or -12 JIC fittings for 3/16 in (4.8 mm), 1/4 in (6.4 mm), 3/8 in (9.5 mm), 1/2 in (12.7 mm), 3/4 in (19.1 mm) hoses |